Micro Cooling Fan Test Method

Date: 2015-7-22   Click: 1914 Times

1. Current: "Micro Cooling Fan" current measurement continues to rotate after 3 minutes
2. Speed: The speed measurement continues to rotate after 3 minutes
3. Start voltage: Turn the switch "ON", the voltage fan can start operation
4. Input power: "Micro Cooling Fan" input power measurements continue to rotate after 3 minutes
5. Lock Current: can lock the machine fan, lock current locking three minutes in the fresh air of determination
6. Air flow rate data and pressure data measured according to "AMCA Standard" or DIN24163 rule, the data measured in the double pressure compartment, and shall be measured on each side of the cabin pressure is the pressure data
7. Noise Standards: "Micro Cooling Fan" noise standard test reference DIN45635 standard, measured in a soundproof indoors, the microphone is placed at one meter fan